Typically RTL’s Chemical Biological Radiological Nuclear protection systems are part of a Life Support System (LSS), which combines it with HVAC but it can also be provided as a standalone system.
A typical CBRN protection system includes one common NBC / CBRN Filter for the platform, and it offers 3 Protection Modes:

  • Overpressure Protection: crew cabin is over pressurized by filtered air and there is no need to use individual protection
  • Collective Facemasks Protection: when crew cabin can't be over pressurized, filtered and conditioned (also cooled / heated if part of a LSS) air is delivered to each individual NBC Facemask.
  • Hybrid Protection: simultaneous Overpressure & Collective Facemask Protection is used mainly in preparation for hatch or ramp opening in a contaminated area.

RTL’s CBRN protection systems offer the latest NBC / CBRN protection technologies and special features, assuring safe operation for extended periods of time and reduced Life Cycle Costs. These include:

  • NATO AEP-54 Compliance offers maximum safety including against Toxic Industrial Chemicals (TIC)
  • Advanced Particles / Dust Separation technology reduces the NBC / CBRN Filter (HEPA stage) dust clogging
  • Relative Humidity Reduction (RHR) System reduces the NBC / CBRN Filter (chemical stage) clogging by air humidity
  • NBC Filter Bypass Valve  allows safe and easy engagement / disengagement of the NBC / CBRN Filter - increases Filter life
  • Exchangeable Pre-Filter  - a concentric low cost filter (additional to the HEPA & chemical stages) saves NBC / CBRN Filter replacements and minimize the life cycle costs and logistics
  • Dynamic Overpressure & Air-Quality Control System minimizes the ambient airflow through the NBC / CBRN Filter and increases its life, while keeping safe overpressure and adequate air-quality in the crew cabin
  • NBC / CBRN Filter Indicator provides reliable indication for NBC / CBRN Filter replacement
  • Computerized control that allows flexibility in changing operational features by software upgrade
  • Networking with main vehicle computer
  • Diagnostics
  • Integrated Chemical / Radiation Detection Systems (CDS / RDS) offer safe detection and automatic operation of the NBCS 

 